Connection refused

Symptom: transport error: connection refused or failed to connect

Causes:

  • Broker not running. Start it: fila-server or docker run -p 5555:5555 ghcr.io/faiscadev/fila:latest
  • Wrong address. Default is localhost:5555. Check your connection string.
  • Firewall blocking port 5555. Verify: nc -zv localhost 5555
  • In Docker: use host.docker.internal:5555 from containers, not localhost

TLS errors

Symptom: tls handshake error, certificate verify failed, or unknown ca

Solutions:

  • Self-signed cert: Provide the CA certificate to the SDK (with_tls_ca("ca.crt"))
  • System trust store: Use with_tls() (no CA path) if the broker’s cert is issued by a public CA
  • Expired cert: Check cert expiry: openssl x509 -in server.crt -noout -enddate
  • Wrong hostname: The cert’s CN/SAN must match the hostname you’re connecting to
  • mTLS required: If the broker requires client certs, provide both client cert and key

Authentication failures

Symptom: UNAUTHENTICATED error status

Solutions:

  • Missing API key: Set api_key / with_api_key() on your client connection
  • Wrong key: Verify the key matches what’s configured on the broker
  • Key revoked: Check if the key was deleted. List keys: fila auth list
  • Permission denied (PERMISSION_DENIED): The key exists but lacks permission for the queue. Check ACLs: fila auth acl list

Queue not found

Symptom: NOT_FOUND error status on enqueue or consume

Solutions:

  • Queue doesn’t exist. Create it: fila queue create <name>
  • Typo in queue name. List queues: fila queue list
  • In clustered mode: if you get UNAVAILABLE instead of NOT_FOUND, the node is still starting up — retry after a moment

Consumer timeout

Symptom: Consumer stream hangs with no messages delivered

Causes:

  • Queue is empty. Check depth: fila queue inspect <name>
  • All messages are leased to other consumers. Check pending count in queue stats.
  • Visibility timeout expired and messages were re-queued. Increase timeout or process faster.
  • Throttle rate limit hit. Check throttle config: fila config list

Message redelivery

Symptom: Same message delivered multiple times

Causes:

  • Visibility timeout expiry: If a consumer takes too long to ack, the message is re-delivered. Solution: ack promptly, or increase the visibility timeout.
  • Nack without DLQ: If on_failure returns { action = "retry" }, the message goes back to the queue. After enough retries, consider dead-lettering.
  • Consumer crash: Leased messages are re-delivered after visibility timeout. This is by design — at-least-once delivery.

Best practice: Make consumers idempotent. Use msg.id as a deduplication key.

Lua script errors

Symptom: Warning logs about script failures, circuit breaker tripping

Solutions:

  • Syntax error: Validate before setting: fila queue create test --on-enqueue 'function on_enqueue(msg) return {} end'
  • Runtime error: Check logs for the specific error. Common: accessing nil headers, type mismatches.
  • Timeout: Script took too long. Default limit is 10ms. Simplify the script or increase lua.default_timeout_ms.
  • Memory limit: Script uses too much memory. Default is 1MB. Check for unbounded table growth.
  • Circuit breaker: After 3 consecutive failures, scripts are bypassed for 10 seconds. Fix the script to reset the breaker.

High memory usage

Solutions:

  • Check queue depths: fila queue inspect <name>. Large queues consume memory.
  • RocksDB block cache can be tuned via configuration.
  • In clustered mode, each node replicates data for its assigned queues.

Cluster issues

Symptom: Node not joining cluster, split-brain, leader election failures

Solutions:

  • Node not joining: Check cluster.peers config — all nodes must list each other’s cluster addresses (port 5556, not 5555).
  • Bootstrap: Exactly one node should have bootstrap = true. Start it first.
  • Network: Verify nodes can reach each other on the cluster port: nc -zv node2 5556
  • Node ID: Each node must have a unique node_id. Duplicates cause undefined behavior.